Vaillant Boiler Fault Codes List

Message Possible cause
F.00 Interruption: Flow sensor Flow temperature sensor defective or not connected
F.01 Interruption: Return sensor Return temperature sensor defective or not connected
F.10 Short circuit: Flow sensor Flow temperature sensor defective or has short-circuited
F.11 Short circuit: Return sensor Return temperature sensor defective or has short-circuited
F.20 Safety switch-off: Temperature limiter Maximum temperature at the flow/return temperature sensor is too high when the safety cut out function is operating using the NTC
F.22 Safety switch-off: Low water pressure No/insufficient water in the product or the water pressure is too low
F.23 Safety switch-off: Temp. spread too large Temperature spread too great. Water circulation too low
F.24 Safety switch-off: Temp. incr. too fast Temperature increase too fast
F.25 Safety switch-off: Flue temp. too high Flue gas temperature too high
F.26 Fault: Fuel valve not working Gas valve assembly stepper motor defective or not connected
F.27 Safety switch-off: Flame simulation Monitoring electrode reports an incorrect flame
F.28 Start-up failure: Ignit. unsuccessful Failure during start-up or ignition unsuccessful. Gas pressure monitor or thermal cut-out has been triggered.
F.29 Operating failure: Ignit. unsuccessful Gas supply interrupted intermittently. Re-ignition failed.
F.32 Fault: Fan Fan defective or not connected
F.49 Fault: eBUS Undervoltage on the eBUS
F.61 Fault: Fuel valve actuation The gas valve assembly cannot be actuated
F.62 Fault: Fuel valve switch off delay Delayed switch-off sequence for the gas valve after the flame is extinguished
F.63 Fault: EPROM EEPROM faulty
F.64 Fault: Electronics/sensor Electronics, safety-relevant sensor or cable defective
F.65 Fault: Electronics temp. Electronics defective or too hot due to external influences
F.67 Fault: Electronics/flame Implausible flame signal
F.68 Fault: Flame signal un stable Flame monitor reports an un stable flame signal
F.70 Fault: Invalid Device Specific Number Incorrect/missing Device Specific Number or incorrect/missing coding resistor
F.71 Fault: Flow sensor Flow temperature sensor re turns implausible values
F.72 Fault: Flow/return sensor Temperature difference between flow and return temperature sensor is too great
F.73 Fault: Water press. sensor (signal too weak) Water pressure sensor reports that the water pressure is too low
F.74 Fault: Water press. sensor (signal too strong) Water pressure too high
F.75 Fault: Pump/ water shortage Insufficient pressure jump de tected when starting the pump
F.77 Fault: Flue non-ret. valve/condens. pump No flue non-return flap feed back; condensate pump over flow
F.78 Interrupt.: DHW outlet sensor on ext. contr. UK link box is connected without the domestic hot water temperature sensor being bridged
F.83 Fault: NTC temp. gradient Temperature difference between flow and return temperature sensor is too small
F.84 Fault: NTC temp. diff. implausible Temperature difference is im plausible
F.85 Fault: NTCs fitted incorrectly Flow/return temperature sensors returning incorrect/implausible values
Communication fault Communication fault between the display and the PCB in the electronics box